Key features:

Pump housing: Stainless steel

Voltage: 230 VAC / 50Hz 

Input power: 1000W 

Max. flow rate: 3500l/h

 Max. pressure:  4.4 bar 

Max. self-priming suction height: 8m

 Cable length: 1.2m

 Weight: 6.32 kg 


https://vonroc.nl/amfile/file/download/file/238/product/2515/

Related product:

  • GP525AC
  • GP527AC
  • GP528AC
  • GP804AA
  • GP805AA
  • GP806AA
  • GP807AA
  • GP808AA


Most common issue, and solutions:

Problem: Pump does not start 


Cause: No mains supply 

Remedy: Check mains supply 


Problem: Pump is active but no water is being delivered (after being started for more than 5 minutes) 


Cause: he pump is not fully filled with water 

Remedy: Re-fill the pump with water and check the suction hose foot valve 


Cause: Air in the suction hose 

Remedy: Check sealing of various joints of the suction hose 


Cause: Water level is too low

Remedy:  Adjust installation height of the pump (< 8 m) 


Cause: Suction hose, foot valve, pre-filter or pump is blocked 

Remedy: Clean suction hose, foot valve, pre-filter or pump



Problem: Insufficient pressure 


Cause: Incorrect pump type 

Remedy: Select suitable pump 


Cause: The suction hose is too long or with too many bends, suction hose diameter is not selected as required 

Remedy: 25mm, 32mm or 38mm (inner diameter) suction hose must be used to achieve maximum flow rate. Make the suction hose shorter 


Cause: Suction hose, foot valve, pre-filter or pump is blocked 

Remedy: Clean suction hose, foot valve, pre-filter or pump


Cause: The outlet hose is incorrectly or incorrectly installed 

Remedy: Check the outlet hose and connections. The larger the diameter of the hose and the hose connection, the greater the flow. The lower the delivery height, the greater the flow 


Problem: Pump will not start or stops during use 


Cause: Thermal overload safety switch has activated 

Remedy: Disconnect from the power supply, leave for 5 minutes and clean suction hose, foot valve, pre-filter or pump 


Problem: Pump switched off after short operating periods 


Cause: Power has tripped 

Remedy: Check fuses and electrical connections 


Cause: Water too hot 

Remedy: sure that the water temperature has not exceeded the maximum of 35°C 



FAQ:

NONE 


Other questions/comments:

NONE 


Spareparts (Number of part to be replaced plus selling price (excluding shipping costs)

  • Part 2 - Drain plug - 5 euro